Mobile CommunicationsEDACS BCU/CALBilling Correlation Unit/Centralized Activity LoggerSystem and Installation ManualLBI-38965
LBI-38965103. SPECIFICATIONS3.1. COMMON BCU AND CAL OPERATIONAL SPECIFICATIONS3.1.1. EDACS System InterfaceThe BCU/CAL interfaces to EDACS via a fu
LBI-38965113.2.2. Billing ArchitectureThe EDACS billing system architecture is shown in Figure 3. Each IMC is connected to a BCU/CAL via a high-spee
LBI-38965123.2.3.1. RF Channel Usage (Air Time)The basic unit of RF channel usage for billing purposes is a channel assignment. One or more working
LBI-3896513Channel assignment and channel drop messages contain the following information:• Date and time of event to the nearest tenth of a second• T
LBI-3896514The three configuration files can be created by running BCS on a BCU/CAL used as a master. Then, these files can becopied to the appropria
LBI-38965153.2.3.10. Call ProcessingThis section contains specifications on the BCU's call processing capability.CDR ProcessingA record of each
LBI-38965163.3. CAL OPERATIONAL SPECIFICATIONSThis section outlines the specifications that are unique to the CAL personality. Refer to Figure 4 for
LBI-38965173.3.3. CAL Operation OverviewAs new RARs enter the system, they are dispatched to an appropriate site handler which reformats and queues t
LBI-38965184. INSTALLATION4.1. HARDWARE INSTALLATIONCAUTIONTurn off the power before removing or installing VMEbus boards. Removing or reinstalling
LBI-3896519If the BCU/CAL is being connected to a network, plug a MAU (either coaxial or twisted pair) into the 15-pin femaleconnector labeled "E
LBI-389652TABLE OF CONTENTS1. INTRODUCTION...
LBI-3896520The following table summarizes the configuration files contained on Installation Diskette 4. These files are provided intemplate form, and
LBI-3896521Network routes are specified in the following form:type destination_ip gateway gateway_ipTable 4 - ROUTES.DAT File ParametersParameter Mean
LBI-3896522Export entries are specified in the following form:directory client_ipTable 5 - EXPORTS.DAT File ParametersParameter Meaningdirectory Direc
LBI-3896523Table 6 - CAL.DAT File ParametersParameter MeaningSITE.ss.PASSWDSpecifies the System Manager password to be used for logins to/from this si
LBI-38965244.2.2. Initial InstallationThe following section discusses software installation on a new BCU/CAL. An example of the expected terminal di
LBI-3896525INSTALLATION 1. Insert Installation Diskette 1 into the BCU/CAL floppy disk drive. 2. Apply unit power, and observe the user console. The
LBI-3896526USER ACTION: Remove Installation Diskette 2. Insert Installation Diskette 3. Press the Enter key.<LOADER> Floppy disk has been mou
LBI-3896527*************************************************************** Welcome to the EDACS BCU/CAL. **
LBI-3896528USER INFORMATION: Enter “ls” to observe the root level directory files and subdirectories which were createdduring the software installati
LBI-3896529Offload time = 00:00:00Tape logging = OffCDR archive(s) lifetime = 7IMC time synchronization = OffRAR activity logging = OffRAR maximum fil
LBI-389653TABLE OF CONTENTS (Cont.)3.3. CAL OPERATIONAL SPECIFICATIONS...
LBI-3896530<LOADER> Loading file 01.02/loads/BC_A.SX from the hard disk... *<LOADER> First load complete. 393126 bytes loaded.<LOADER&g
LBI-38965314.2.3. Software UpgradesSoftware upgrades are similar to the initial installation procedure discussed above. Each time the BCU/CAL boots,
LBI-3896532For each site defined in the CAL.DAT file, configure the associated port on the terminal server as follows:Server>> change port port
LBI-3896533Configuration TipsIf all 16 ports of a terminal server are needed for System Manager interface, first configure 15 of them using a “dumb”te
LBI-38965A-1APPENDIX AEDACS BILLING (CDR) FORMAT
LBI-38965A-2This appendix defines the EDACS call detail record (CDR) format for the collection of system resource usage data in amultisite trunked rad
LBI-38965A-35. RECORD LAYOUT5.1. SINGLE-SITE CALLSThe following diagram shows the layout of the fields in a basic CDR for a single-site call. The t
LBI-38965A-45.4. CALCULATING THE NUMBER OF BYTES IN A CDRNote that the final linefeed character which terminates the record is not shown in these dia
LBI-38965A-56. CALL TYPE DEFINITIONSTable A.2 contains the typical values of the call type (CDR field 6). Note that many call types are invalid, and
LBI-3896541. INTRODUCTIONThis manual contains installation instructions, physical and functional descriptions, specifications, and usage informationf
LBI-38965A-6Table A.2 - Call Types (Cont.)Call Type Description Valid withHex Decimal Rec. Type45 69 Group, Digital Voice, System All Call, TX Trunked
LBI-38965A-7Call Type Bit FieldsThe call type values have been selected so that individual attributes of the call type may be associated with single-
LBI-38965A-87. CDR FILE TOPICSCDR files are located in the 1.2/cdr directory. All closed CDR files are named tdddhhmm.CDR, whereddd = Day of the yea
LBI-38965B-1APPENDIX BPHYSICAL CONFIGURATION DETAILS
LBI-38965B-2This appendix contains information about jumper settings and cable pinouts for the BCU/CAL.1. JUMPER SETTINGSJumper settings for the BCU/
LBI-38965B-3J1 J22 * AM27C040U22 U30FactorySetP1 P2J5J6J3System ControllerFactorySetSerial Port 4J8 J9J7Figure B.1 - TVME 147SA1 Single-Board Computer
LBI-38965B-4Terminators RemovedFigure B.2 - TVME 712/M Transition Module(Terminators Installed)Figure B.3 - TVME 147P2 Adapter Board
LBI-38965B-5Figure B.4 - fv5310 Main Board
LBI-38965B-6Figure B.5 - fv5310 Mezzanine CardPORT 0: DTE WITH DCE PROVIDING RX AND TX CLOCKS*IMC/CAM INTERFACE
LBI-38965B-7J6J7J50123401234SCSI ConnectorRN2RN1(Terminators Removed)ParitySCSIID = 2(Factory Set)Motorstart onpower-upFigure B.6 - Maxtor MXT-1240S H
LBI-3896551.1. BCU FUNCTIONAL DESCRIPTIONThe main function of the BCU is to generate call detail records (CDRs) to be transferred to an external bill
LBI-38965B-8PwrSCSI Conn.Factory Set JumpersRA2RA1TEAC FD235HS-711ID2ID1ID0SCSI ID = 1(TerminatorsRemoved)Figure B.7 - Teac FD235HS-711 Floppy Disk123
LBI-38965B-92. CABLE PINOUTSBCU/CAL Internal Wiring - VME P2 Backplane connector (of WANServer card) to DB-25 connectors on backplateTable B.1 - WANS
LBI-38965B-10Table B.3 - WANServer Port 2Table B.4 - WANServer Port 3VME P2ConnectorDB-25FConnectorSignal Name FunctionA-18 02 XMT-P Transmit DataC-1
LBI-38965B-11Table B.5 - BCU/CAL HDLC Loopback Cable SpecificationDB-25M ConnectorM/W BCU/CAL Port 1DB-25M ConnectorM/W BCU/CAL Port 0Signal Name Func
LBI-38965B-12239XPIN 1PIN 13PIN 14PIN 2551PIN 1TBD.75NOTES:1. FABRICATE CABLE TO LENGTH INDICATED. NOTE CONNECTOR ORIENTATION CAREFULLY. W
LBI-38965B-13J1J2 J3J4J5J6 J7J8J9J10J11J12J13J14J15J16 4203840G1TERMINAL SERVER 1 4203840G1TERMINAL SERVER 21 J33PORT 1PORT 2PORT 3POR
LBI-38965B-14Computer TerminalASCII KeyboardA7P2A7 INMAC H353-2A7P1PORT 1/CONSOLESERIAL PORT 3SERIAL PORT 2SERIAL PORT 4SCSI INTERFACEETHERNETPRINTERJ
LBI-38965C-1APPENDIX CFAULT TOLERANCE
LBI-38965C-2Figure C.1 shows the architecture for a fault tolerant EDACS billing system.RFSystemConsoleTerminalMIM(Primary)MIMBCUBCUCAMCAMAREAIMCConso
LBI-3896562. PHYSICAL DESCRIPTION AND COMPATIBILITYThis section outlines the specifications, depicts the physical architecture, and provides compatib
LBI-3896572.2. BCU/CAL ARCHITECTUREThe BCU/CAL's internal architecture is shown in Figure 2. The individual components and their primary functi
LBI-389658The BCU/CAL is based on a VMEbus computing platform with the following components:CPUTechnico TVME 147 single-board computer based on a 6803
LBI-3896592.3. COMPATIBILITYThe BCU/CAL software is compatible with the following IMC and System Manager versions:• IMC Software V4.01 and later• IMC